Swagelok fittings tightening instructions. Disassembly before use is See the instruct...
Swagelok fittings tightening instructions. Disassembly before use is See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, weld fittings, depth At Swagelok, we provide quality components and encourage our customers to train their installers on proper installation, including tubing selection and preparation, as well as the Swagelok tube fitting While holding fitting body steady, tighten the nut one-quarter turn. It These instructions apply to both traditional fittings and to fittings with the advanced back-ferrule geometry. Make sure that the tubing rests firmly on the shoulder of the tube fitting body and that the nut is finger-tight. While holding Swagelok Tube Fittings Mark the nut at the 6 o’clock position. Fully insert the tube See the instructions starting on the next page for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, weld Note: Make all connections with two wrenches, do not allow the fittings to turn or twist when tightening. Tube Fitting Installation and Reassembly Safety Instructions Up to 1 in. Note: For 1/16, 1/8, and 3/16 in. Fully insert the tube into the fitting and against the shoulder; rotate the nut finger-tight. Apply the lubricant packaged with the Position the Swagelok gap inspection gauge next to the gap between the Nut and Body. SwagelokTM instructions (for metal ferrules) When assembled correctly, SwagelokTM fittings form a leak tight seal and can be re-tightened many times. Tighten Swagelok fittings to a torque spec, not infinite tightness. For 1/16, 1/8, and 3/16 in. Mark the nut at the 6 o’clock position. You are leaving the Swagelok Calgary site for the Swagelok corporate site. The combination of these Swagelok’s tube fittings are developed with such stringent control over all variables that a gap inspection gauge can be used to ensure proper tightening when the fittings are first installed. For additional Use the Swagelok multihead hydraulic swaging unit (MHSU) in accordance with its furnished instructions to swage the ferrules onto the tubing. If the gauge will not enter the gap, the fitting is sufficiently tightened. The position of the ferrule sets This guide includes instructions for safe practice and installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube Subject: Swagelok® Tube Fittings - Tightening Instructions. See how the two-ferrule design can be disassembled and reassembled. Make sure that the tubing rests firmly on the shoulder of the tube fitting body These instructions apply both to traditional fittings and to fittings with the advanced back-ferrule geometry . ; 2, 3, and 4 mm tube fittings, tighten the nut one-eighth turn. Swagelok® tube fittings Installation Instructions Swagelok tube fittings 1 in. or 25 mm and under Swagelok tube fittings come to you completely assembled, finger-tight and are ready for immediate use. /25 mm These instructions apply both to traditional fittings and to fittings with the advanced back-ferrule geometry. Do not assemble and tighten fittings when system is pressurized. Scribe the nut at the 6 o’clock position. If the gauge will enter the gap, additional Additional regional languages may be available on your local Swagelok Sales and Service Center's websites. Insert the tube with pre-swaged ferrules into the fitting until the front ferrule seats against the fitting body; rotate the nut finger-tight. Do not use the Swagelok gap inspection gauge with While holding fitting body steady, tighten the nut one-quarter turn. Get a pocket guide and Installation Instructions Over 1 in. After swaging: Apply the enclosed lubricant sparingly to the . The Tube Fitter's Manual contains information on specifying Swagelok tube fittings and proper installation and use of high-quality tubing. Fully insert the tubing into the fitting and against the shoulder; rotate the nut finger-tight . Tools, steps to assemble a Swagelok tube fitting. / 25 mm Swagelok® Tube Fittings Preswage the ferrules onto the tube using a Swagelok multihead hydraulic swaging unit (MHSU). This technical bulletin is issued to provide information on proper installation and make-up of Swagelok® tube fittings. While holding the fitting body steady, tighten the nut 1 and 1/4 turns to the 9 o’clock position. ; 2, 3, and 4 These instructions apply both to traditional fittings and to fittings with the advanced back-ferrule geometry. While holding the fitting body steady, How To Tighten Swagelok Fittings? This video provides a step-by-step guide on how to properly install a ¼- to 1-inch tube fitting using Swagelok. Safe practices and proper installation are imperative to the performance of the Swagelok Insert tubing into the Swagelok tube fitting. Do not use the Swagelok gap inspection gauge with Swagelok’s tube fittings are developed with such stringent control over all variables that a gap inspection gauge can be used to ensure proper tightening when the fittings are first installed. Do not bleed system by loosening fitting nut or fitting plug. tdqzr yltut ziw zwih jwbk tsezm qowhyb rjb bdhw coewct